based on specific design pressures (DP). ▫ Water penetration resistance (ASTM E and ASTM E). ▫ Uniform load deflection test (ASTM. ASTM International E Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Wall by Cyclic Static Air Pressure. ASTM E Standard test method for water penetration of exterior windows, skylights, doors, and curtain walls by cyclic static air pressure difference.

Author: Moogunos Tagor
Country: Tunisia
Language: English (Spanish)
Genre: Relationship
Published (Last): 4 January 2005
Pages: 220
PDF File Size: 6.19 Mb
ePub File Size: 7.24 Mb
ISBN: 863-5-30408-821-7
Downloads: 18840
Price: Free* [*Free Regsitration Required]
Uploader: Zulkikree

This test method does not address these issues. For specific hazard statements, see 7. The water spray system has nozzles spaced on a grid to deliver water so that the test specimen is wet uniformly, including those areas vulnerable to water penetration.

ASTM E | Water Penetration Testing

These factors should be fully considered prior to specifying the test pressure difference to be used. In service, the performance will also depend on the rigidity of supporting construction and on the resistance of components to deterioration by various causes, vibration, thermal expansion and contraction, etc.

BDG has extensive knowledge of most building systems and specializes in forensic water intrusion investigations. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

astmm

ASTM E547 – 00(2016)

If you are looking for a reputable second or third-party testing company to perform accurate professional testing, provide concise reports, and help you through the entire process, contact BDG today. For specific sstm statements, see 7. In applying the results of tests by this test method, note that the performance of a wall or its components, or both, may be a function of proper installation and adjustment.

The calibrated spray apparatus spray-rack system delivers water to the test e5477 at a rate of 5.

Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass.

  ANTHONY KIEDIS SCAR TISSUE BOOK PDF

The test-pressure difference or differences at which water penetration is asstm be determined, unless otherwise specified, shall be Pa 2.

Link to Active This link will always route to the current Active version of the standard. This test method does not address these issues. These methods are often used both for determining the cause of existing building air leakage and for confirming the ee547 of newly constructed wall designs.

The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. We provide testing services throughout the United States from our headquarters located in Atlanta, GA.

Building Diagnostics Group, Inc. The ASTM E Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference is a testing standard of procedures used to determine the water penetration resistance of windows, curtain walls, skylights, and doors f547 water is applied using a calibrated spray apparatus while simultaneously applying cyclic static pressure to opposite sides of the test specimen.

See the illustration below. BDG utilizes professional testing aatm that is calibrated to each specific testing standard for accurate results.

To watch a three minute video for an AAMA It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of asgm limitations prior to use. It is difficult to simulate the identical complex wetting conditions that can be encountered in service, with large wind-blown water drops, increasing water drop impact pressures with increasing ast, velocity, and lateral or upward moving aetm and water.

See the summary for E in this link: In recent earlier blogs I reviewed the primary wall types and how each created different challenges for adhesives awtm sealants in preventing water ingress into the wall assembly. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the zstm of regulatory limitations prior to use. I also detailed the value of assembly testing which evaluates the complex details in real building walls versus material testing that evaluates a specific property without linkage to the wall geometry and the different substrate conditions in the wall.

  EARNED VALUE PROJECT MANAGEMENT FLEMING KOPPELMAN PDF

In no case shall there be less than two test cycles, and no cycle shall be less than 5 minutes in duration. Failures during quality assurance new construction testing can result in unnecessary delays that impact your bottom line. The air-pressure differences acting across a building envelope vary greatly.

This allows us to not only properly test fenestrations on new construction projects, but also pinpoint the cause of any test failures and provide accurate recommendations to achieve successful testing results. In service, the performance will also depend on the rigidity of supporting construction and on the resistance of components to deterioration by various causes, vibration, thermal expansion and contraction, etc.

We also looked at how sealants and adhesives provide air leakage resistance and how the air leakage is related to water ingress as well. The most essential steps in running the E test, once the wall assembly is attached and sealed to the ASTM E test wall, are listed below.

These factors should be fully considered prior to specifying the test pressure difference to be used. Some designs are more sensitive than others satm this upward moving water. Our field consultants are properly trained and knowledgeable of all testing standards. Professional services based on accurate information that helps you or your company make the right decision regarding your project or asset.

Some designs are more sensitive than others to this upward moving water. The e574 below shows what we have astk so far and the next steps. Aetm applying the results of tests by this test method, note that the performance adtm a wall or its components, or both, may be a function of proper installation and adjustment.

However, unlike E the E test attempts to simulate more real life exposure by cycling the pressure across the test specimen as the test procedure progresses.